Which of the following statements are incorrect about the UPS 5000-A-400/500K? (Multiple Choice)
Which of the following statements are true about the overload capabilities of the various capacity models of the UPS2000-A series (6 kVA to 10 kVA) in normal mode? () (Multiple Choice)
Battery strings of different brands and the same capacity can be used in parallel.
The UPS2000-G series (6 kVA to 20 kVA) supports backup power supplied from battery packs and battery racks. Battery packs can be mounted on racks to save installation space.
Which of the following functions do the FusionModule800 and Fusion Mod ule500 support? () (Multiple Choice)
Which of the following statements are correct about the UPS5000-E overload capacity? (Multiple Choice)
The input power factor (full load) of the UPS5000A is (), which can efficiently reduce the pollution to the power grid and save the preceding power distribution investment.
What is the cooling capacity of a single air conditioner used by the Fusion Mod ule800? ()
When using a UPS5000-E (50 kVA power module) with the actual load of 160 kW, 1+1 rack redundancy, and single UPS backup solution, each rack uses three battery strings, each battery string consists of 40 batteries, and the main switch box capacity is ().
Which of the following alarms can the UPS5000-A dry contact expansion card set? (Multiple Choice)
The UPS2000-G series (6 kVA to 20 kVA) supports up to () UPSs in parallel, providing excellent scalability.
The control unit of the UPS5000-A adopts 1+1 redundancy. A faulty control unit can be smoothly switched to the other, which can prevent the occurrence of single-point failures and improve the power supply reliability.
The Fusion Mod ule500 and FusionModule800 support the use of 24 U and 42 U cabinets.
Which of the following are the functions of the SCT configurator? () (Multiple Choice)
The UPS2000-G-20KRTL is rack/tower convertible. The rack-mounted model is () high.
If a UPS system is configured with a single 50 mm2 (209 A) cable, the maximum carrying capacity can be ():
Which of the following voltage systems does the UPS5000-E support? (Multiple Choice)
Which of the following statements are correct about the UPS5000-A-500K efficiency? (Multiple Choice)
Which of the following is not a configuration option of the 20-kVA UPS2000-G? ()
For the 6-kVA UPS2000-G, a 1+1 parallel system requires () DB15 parallel cables to ensure that each UPS is connected by at least two parallel cables and to enhance the parallel system reliability.
The output THDv of the UPS5000-E (50 kVA power module) is (). (Multiple Choice)
The number of battery strings for the UPS5000-A can be adjusted. To avoid replacing the whole battery string due to one faulty battery and solve the battery maintenance difficulty of traditional UPSs.
By default, how many PDUs are configured for one cabinet of the FusionModule2000? ( )
The UPS5000-A has an industry-leading efficiency. It keeps a high efficiency within a wide load range, which greatly reduces the operating expense (OPEX) for clients. The highest efficiency can be().
Batteries of different discharge currents have different requirements for the cutoff voltage. Typically, the () the discharge current is, the () the cutoff voltage is.