Which zones accurately describe the zoning requirement for replication connectivity to be established when the source array is in Legacy Port Mode and the target array is in Virtual Port Mode?
Assume a storage administrator is using the recommended storage profile. What describes the distribution of volume data residing in an SC series storage array that has 15K and 7K as the back-end?
A customer wants to configure a threshold alert definition. Which types of definitions can be configured?
What is used for migrating data from legacy system volumes to SC default provisioned volumes?
You want to create a notification setting to help monitor how full the volumes are on an SC9000 system. In Dell Storage Manager (DSM), where would a schedule to only trigger these alerts during business hours be set up?
When you enable Storage Profiles on a SC with two tiers of flash drives, which storage profile will appear in addition to the standard storage profiles?
ON NO: 83
When connecting directly to an SC7020 storage array using Dell Storage Manager Client, which host/IP address is entered into the login screen?
You are deploying a new SC9000 system running Storage Center OS 7.2. At which drive size does the system require you to begin running dual redundancy on both SSDs and HDDs?
To achieve redundancy, how many connections from the same SC Series controller are required per fault domain?
You are deploying a new SCv2020 system with four additional SCv100 expansion enclosures. What is the spare-to-managed drive ratio?
There has been a request to add iSCSI functionality to a SC9000 array for replication. SC is currently using slots 4 and 5 for SAS back end. Slots 2 and 3 for Fibre Channel front end.
How many slots are available for new half-height I/O Cards?
What is the maximum number of disks that can be supported by an SC4020 running SCOS 6.6.4 or later?
A customer has asked you to confirm whether their volumes will remain online even after a controller failure. What is the correct sequence of steps to perform a controller failover test?
You recently added a second Storage Center to your network. Both systems were added to DSM, and you can ping the iSCSI ports of the remote system. You are planning to replicate between your two systems, but you cannot get the Replication Wizard to launch.
What item is missing?
Which Live Volume Requirement or Best Practice is necessary for disaster recovery?
A customer has two production sites with one storage administrator at each site. The customer wants to replicate data between their SC9000 storage arrays. Each administrator uses a workstation with the Dell Storage Manager Client to manage their respective system. Now, the CEO wants data replicated between both sites.
What is the first step to configure replication between sites?
While installing a SC system the customer reports that it will house a database that has a nightly database backup that starts at 6 pm. What system configuration change can you make to lessen the impact of this SQL job?
What is a minimum recommended redundancy to support Controller port level failover?
Refer to the exhibit.
The servers are zoned to best practices. The output of the switch is shown below:
Which is the Physical Zone of Fault Domain B?