Winter Special Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: netbudy65

DES-1241 Specialist - Platform Engineer PowerStore Exam Questions and Answers

Questions 4

A Storage Administrator encounters a Snapshot issue on a Dell EMC PowerStore X system.

The administrator engages support and they determine the Snapshot issue is a known code bug within the OS version of PowerStore code. How can support address the problem in a timely manner?

Options:

A.

Disable the Snapshots feature to avoid encountering the code bug

B.

Upgrade the Snapshot portion of code within the OS

C.

Upgrade the PowerStore with a hotfix that corrects the code bug

D.

Wait for a new full OS release that corrects the code bug

Buy Now
Questions 5

What describes Dell EMC PowerStore heat dissipation?

Options:

A.

X systems have higher heat dissipation specifics than T systems

B.

Higher model numbered systems have lower heat dissipation specifications than lower model numbered systems

C.

T systems have higher heat dissipation specifics than X systems

D.

Lower model numbered systems have lower heat dissipation specifications than higher model numbered systems

Buy Now
Questions 6

Which Dell EMC PowerStore network uses an appliance backplane?

Options:

A.

ICD

B.

MPIO

C.

Inter-node

D.

Inter-cluster management

Buy Now
Questions 7

A Storage Administrator needs to add drives to a base enclosure of a Dell EMC PowerStore 7000T system. The system currently contains 10 750 GB NVMe SCM drives.

Which drive configuration maximizes the base enclosure capacity?

Options:

A.

11 15360 GB NVMe SSD drives in slots 10 - 20

B.

13 15360 GB NVMe SSD drives in slots 10 - 22

C.

11 750 GB NVMe SCM drives in slots 10 - 20

D.

13 750 GB NVMe SCM drives in slots 10 - 22

Buy Now
Questions 8

What describes Dell EMC PowerStore X front-end cabling?

Options:

A.

Uses internal VMware virtual switching and does not require a management network

B.

Storage and management use the same LACP bonded cable connection

C.

Uses VLTi data switch interconnectivity to support vMotion networks

D.

Management and discovery use the same cables and connections as storage

Buy Now
Questions 9

What is the alert severity if the license expiration date is within a week?

Options:

A.

Warning

B.

Minor

C.

Major

D.

Information

Buy Now
Questions 10

What is the maximum number of expansion enclosures that a single Dell EMC PowerStore appliance supports?

Options:

A.

2

B.

3

C.

4

D.

6

Buy Now
Questions 11

Under which condition does the Dell EMC PowerStore equipment in the rack require additional stability?

Options:

A.

Low temperatures

B.

Unstable humidity

C.

Unstable environments

D.

High temperatures

Buy Now
Questions 12

What is an alternative way to collect logs instead of using the Dell EMC PowerStore manager GUI?

Options:

A.

Data Collect using Service Container

B.

USB stick inserted into the system

C.

Data Collect using vCenter

D.

Discovery Utility

Buy Now
Questions 13

Correctly order the steps of the embedded module replacement procedure.

Options:

Buy Now
Questions 14

What describes the SAS cabling when adding an expansion enclosure to a Dell EMC PowerStore, for each node and expansion enclosure side?

Options:

A.

SAS cabling goes from existing A ports to new В ports. At the last enclosure, SAS cabling returns from the A ports to the originating node’s B ports

B.

SAS cabling goes from existing A ports to new В ports. At the last enclosure, SAS cabling returns from the A ports to the alternate node’s В ports

C.

SAS cabling goes from existing В ports to new A ports. At the last enclosure, SAS cabling returns from the В ports to the alternate node’s A ports

D.

SAS cabling goes from existing В ports to new A ports. At the last enclosure, SAS cabling returns from the В ports to the originating node’s A ports

Buy Now
Exam Code: DES-1241
Exam Name: Specialist - Platform Engineer PowerStore Exam
Last Update: Nov 21, 2024
Questions: 96

PDF + Testing Engine

$130

Testing Engine

$95

PDF (Q&A)

$80