1z0-902 Oracle Exadata Database Machine X9M Implementation Essentials Questions and Answers

Questions 4

You have configured a multirack Database Machine with two X9M-8 full racks all in a single cluster and storage grid comprising a total of 4 X9M-8 Database servers and 28 X9M-8 Storage servers.

Which two options are true regarding the servers on which Enterprise Manager agents must be deployed in order to monitor all components of this multirack configuration?

Options:

A.

on at least two storage servers in both racks

B.

on only one database server in both racks

C.

on all database servers in the first rack

D.

on all storage servers in both racks

E.

on all database servers and at least two storage servers in both racks

F.

on all database servers in the second rack

G.

on all database servers in both racks and one storage server in each rack

Buy Now
Questions 5

Your customer needs to ensure that their data is available on the Exadata machine during updates. The customer wants to be able to update one server at a time but still be protected against single-node server failure.

What ASM redundancy level should they use?

Options:

A.

Normal

B.

Sparse

C.

High

D.

External

E.

Extended

Buy Now
Questions 6

Which two statements are true about the initial storage configuration after the standard (non-virtualized) deployment of a new Exadata Database Machine with High Capacity storage servers?

Options:

A.

The sparse_ diskgroup is created automatically.

B.

There is free space available on the hard disks inside the database servers for possible extension of the /uoi file system.

C.

The DATA_ and RECO_ ASM diskgroups are built on with DATA on the outer-most tracks and RECO on the inner-most tracks of the physical disk.

D.

There is free space available on flashdisks inside the Exadata storage servers for possible use for storage indexes.

E.

There is free space available on flashdisks inside the Exadata storage servers to configure Exadata Smart Flash Logs.

Buy Now
Questions 7

Which four actions should you take before proceeding with applying updates to your Exadata Database Machine?

Options:

A.

Consult My Oracle Support note 888828.1 to determine the current recommended Exadata software release.

B.

Check the Exadata Critical Issues My Oracle Support note 1270094.1 for any issues not added to the latest version of exachk.

C.

Run exachk and resolve only WARNINGS that you have not seen before.

D.

Run the appropriate patchmgr preqequisite check step for each component being updated.

E.

Run patchmgr --all_comp —autofix —autobackup —upgrade —rolling.

F.

For database servers, perform a server backup using patchmgr —dbnodes db_list_file —backup —rolling.

Buy Now
Questions 8

You have been asked to investigate why an Exadata Database Server stopped communicating on the client network for 10 minutes over the past weekend.

Which command would help investigate this?

Options:

A.

$ ${ORACLE_HOME}/suptools/tfa/release/tfa_home/bin/tfact1 —from _17:00:00 —to _23:59:00

B.

# /opt/oracle.SupportTools/ibdiagtools/netcheck/runDiagnostics.pm —from _17:00:00 —to _23:59:00

C.

# /opt/oracle.ExaWatcher/GetExaWatcherResults.sh —from _17:00:00 —to _23:59:00

D.

# /opt/oracle.SupportTools/exachk/exachk —from _17:00:00 —to _23:59:00

Buy Now
Questions 9

Which are three customer options for hosting the Platinum Services Advanced Support Gateway?

Options:

A.

Install on Oracle Database Appliance.

B.

Provide individual x86 64-Bit gateway hardware.

C.

Install in Oracle Virtual Machine with required hardware.

D.

Purchase the recommended x86 64-Bit gateway hardware from Oracle.

E.

Install on Exadata Engineered System.

Buy Now
Questions 10

Which are two valid reasons for executing an X9M-2 Exadata storage server rescue procedure?

Options:

A.

the failure of physical disk 1

B.

corruption in the / (root) filesystem

C.

the failure of both physical M.2 disks

D.

the failure of physical disk 0 and 11

E.

moving all disks from one cell to another as part of a chassis-level component failure

F.

accidental loss of all data from all griddisks in a storage server

G.

corruption in a normal or high redundancy ASM diskgroup

Buy Now
Questions 11

Exadata X9M enables virtualization using KVM. Which statement is true about virtualization on Exadata X9M?

Options:

A.

Up to 12 virtual guests per X9M-2 database server are supported. If the database server memory has 384GB and Exadata Secure RDMA Fabric isolation is configured 8 guests are supported

B.

Up to 12 virtual guests per X9M-2 database server are supported.

C.

Exadata X9M-8 supports up to 48 virtual guests regardless if Exadata Secure RDMA Fabric Isolation is configured.

D.

Oracle KVM Manager should be installed on at least two Database servers per Exadata rack.

E.

Virtual guests from X8 and earlier can be migrated to X9M using VM Guard.

Buy Now
Questions 12

What is the maximum DRAM capacity you can expand an X9M-2 DB Server?

Options:

A.

1536GB

B.

512GB

C.

2048GB

D.

768GB

E.

1024GB

F.

384GB

Buy Now
Questions 13

You have been notified by your Network Administrator that an upstream switch has been replaced due to a hardware fault. Which command verifies that the client network on your Exadata X9M-2 Database Server is available via both client switches?

Options:

A.

ifconfig -a legrep "re0| re1"

B.

/opt/oracle.SupportTools/ibdiagtools/checkbadlinks.p1 —all

C.

netstat -rn

D.

cat /proc/net/bonding/bondeth0

Buy Now
Questions 14

An Exadata storage server physical disk on an X9M-2 high-capacity full rack entered the predictive failure state. Which two steps must you perform to replace this failed physical disk?

Options:

A.

Replace the failed physical disk.

B.

Add the griddisks back into the ASM diskgroup they used to be a member of.

C.

Identify the griddisks located on the failed physical disk and drop them from the associated ASM diskgroups.

D.

Rebalance the data on the effected griddisks before performing a manual drop command.

E.

Create a new celldisk and new griddisks on the replaced physical disk.

F.

Verify that the griddisks located on the physical disk have been successfully dropped from the associated ASM diskgroups.

Buy Now
Questions 15

What is the minimum Exadata System Software version required for Exadata X9M?

Options:

A.

20.1.1.0.0

B.

19.2.1 0.0

C.

21.2.0.0.0

D.

19.3.0.0.0

E.

18.1.3.0.0

F.

21.3.0.0.0

Buy Now
Questions 16

You have been tasked with replacing a memory module of an Exadata Storage Server and need to power off the affected storage server. Which two commands must you execute to safely power off the storage server in an Exadata X9M Database Machine?

Options:

A.

CeLLCLI> alter cell shutdown SERVICES all on the affected storage server

B.

CeLLCLI> list GRIDDISK where status != 'inactive' on the affected storage server

C.

'crsct1 stop cluster -all' on one of the database servers

D.

CellCLI LIST GRIDDISK ATTRIBUTES name WHERE asmdeactivationoutcome != 'Yes' on the affected Storage server

E.

CellCLI alter GRIDDISK all inactive on the affected storage server

F.

shutdown -h now' on the affected storage server

Buy Now
Questions 17

How do ASM failure groups provide redundancy?

Options:

A.

Failure groups are created for each grid disk to ensure mirror copies are written to the same storage server for faster recovery after a physical disk failure.

B.

Failure groups contain all ASM disks in a single storage server preventing mirror copies being written to the same storage server.

C.

They ensure that the ASM Flex instances are enabled on a maximum of two database servers or VMs per cluster.

D.

Extended Redundancy mirrors data across data centers providing the highest levels of data protection.

Buy Now
Questions 18

What does the following command do?

root@rul6 -]# for j in {01..23} ; do ipmitool sunoem cli "set /SP/network/test ping=192.168.1.1$j'' ; done

Options:

A.

Sets the address for each storage and database server's /SP during installation to enable ping testing from the management network, run from the first database server.

B.

Verifies that the ILOM management network is working before installation of all storage and database servers in a full rack Exadata X9M-2, run from the first database server.

C.

Verifies that the ILOM management network is working after OEDA configuration has completed for all storage and database servers in a full rack Exadata X9M-2, run from the first database server.

D.

Sets the test address for the RoCE network for all storage and database servers in a full rack Exadata X9M-2, run from the first database server.

Buy Now
Questions 19

When receiving an Exadata Database Machine rack on site, which of the following statements is INCORRECT?

Options:

A.

Push Oracle Exadata Rack from behind when moving into place.

B.

Four leveling feet share the load with the casters.

C.

Pushing on the side panels can tip the rack over.

D.

Front casters do not turn, you must steer the unit by moving the rear casters.

E.

Reuse the shipping brackets to permanently mount the rack to the floor.

Buy Now
Questions 20

Which three statements are true about the CELLCLI command?

Options:

A.

It can execute commands on multiple storage servers in parallel.

B.

It has command-line history.

C.

It requires root privileges to create CELLDISKS and GRIDDISKS.

D.

It can be executed on storage servers.

E.

It can be executed using the DCLI utility.

Buy Now
Questions 21

You are planning the monitoring configuration for your Exadata X9M Database Machine.

Which three components are monitored directly through the use of Exadata-specific Enterprise Manager Plug-Ins?

Options:

A.

ASM instances

B.

Hybrid Columnar Compression (HCC) ratios on Extended (XT) storage servers

C.

the storage server ILOM

D.

the Power Distribution Units (PDUs)

E.

Oracle clusterware on the database server

F.

the RDMA over Converged Ethernet (RoCE) switches

Buy Now
Questions 22

Which of the below is NOT a precaution that should be adhered to in order to ensure the site is safe and ready for

Options:

A.

Do not use a flathead screwdriver to disconnect connector locks on LAN cables.

B.

Be sure that each grounding wire used for Oracle Exadata Rack is used exclusively for Oracle Exadata Rack.

C.

Do not install Oracle Exadata Rack near a photocopy machine.

D.

Do not place anything on top of Oracle Exadata Rack.

E.

When using shared grounding, the grounding resistance must not be greater than 10 ohms.

F.

Do not install Oracle Exadata Rack in a location that is exposed to direct sunlight.

Buy Now
Questions 23

Which are two correct statements about backing up Exadata Database Machine?

Options:

A.

Backup of the Oracle Cluster Registry, which also contains Voting Disk information, is automatically maintained on the file system of the first database server.

B.

Backing up Exadata Storage Server Software is critical for restoration.

C.

For high availability, system area can be on the first two disks and M.2 devices.

D.

The M.2 disk is hot pluggable and can be replaced when the power is on, but you will have to restore the system data manually.

E.

Use a snapshot-based backup of an Oracle Exadata Database Machine database server software.

Buy Now
Questions 24

Where should your customer go to find the latest Exadata updates?

Options:

A.

MyOracle Support note Exadata Database Machine and Exadata Storage Server Supported Versions (Doc ID - 888828.1)

B.

MyOracle Support for database and server updates, ULN for OS updates, and Cisco for RDMA over Converged Ethernet (RoCE) switch updates

C.

the Exadata System Software User's Guide Appendix A - Upgrading Oracle Exadata System Software

D.

the patch database in MyOracle Support

Buy Now
Questions 25

Which two options describe the flash memory capabilities of the Exadata X9M-2 database and storage severs?

Options:

A.

4 x 6.4 TB NVMe flash cards on the High Capacity (HC) storage server

B.

4 x 6.4 TB NVMe flash cards on the database server

C.

8x 6.4 TB NVMe flash cards on the Extended (XT) storage server

D.

No flash storage on the database server

E.

8 x 6.4 TB NVMe flash cards on the Extreme Flash (EF) storage server

Buy Now
Exam Code: 1z0-902
Exam Name: Oracle Exadata Database Machine X9M Implementation Essentials
Last Update: Nov 23, 2024
Questions: 85

PDF + Testing Engine

$140

Testing Engine

$105

PDF (Q&A)

$90